Details of Vibration Type Level Switch

Vibration Type Level Switch

Based on that the electronic circuit excites a vibration in the rod probe.
The electronics senses the change of vibration and gives output signal after a selected delay.

RKH-502-1 Rod Type for powder RFM-401-0 Fork Type for liquid
RKH-502-1 Rod Type for powder RFM-401-0 Fork Type for liquid
RFM-301-0 Fork Type for powder RRH-301-0 Fork Type for powder
RFM-301-0 Fork Type for powder RRH-301-0 Fork Type for powder

Characteristic of Vibration Type Level Switch

  • Not affected by temperature, pressure, density, dielectric constant and conductivity. Stable measurement.
  • Material with excellent corrosion resistance and strength, SUS316Ti.
  • LED Display, easy confirmation from outside.
  • Standard application with Fail-safe function
  • Adjustable sensitivity
  • Without mechanical moving part and sealing, Excellent pressure resistance and durability.
  • CE marking
  • Free power supply

Vibration Type Level Switch Catalog Download

Vibration Type Level Switch Catalog Download

Vibration Type Level Switch Dimension Download

R-500 Rod Type for powder
Model type mounting Dimension PDF Dimension DXF
RKH-502-1 Standard Type Screw-in(G1 1/2) PDF DXF
RKH-502-1 Standard Type Flange PDF DXF
RHH-502-1 Heat resistant Type Screw-in(G1 1/2) PDF DXF
RHH-502-1 Heat resistant Type Flange PDF DXF
RKR-5□□-1 Protective Tube Type Screw-in(G1 1/2) PDF DXF
RKR-5□□-1 Protective Tube Type Flange PDF DXF
RKK-5□□-1 Wire Type Screw-in(G1 1/2) PDF DXF
RKK-5□□-1 Wire Type Flange PDF DXF
R-300 Fork Type for powder
Model type mounting Dimension PDF Dimension DXF
RRH-301-0 Standard Type Screw-in(G1 1/2) PDF DXF
RRH-301-0 Standard Type Flange PDF DXF
RFM-301-0 Standard Type Screw-in(G1) PDF DXF
RFM-301-0 Standard Type Flange PDF DXF
RRH-3□□-0 Protective Tube Type Screw-in(G1 1/2) PDF DXF
RRH-3□□-0 Protective Tube Type Flange PDF DXF
RFM-3□□-0 Protective Tube Type Screw-in(G1) PDF DXF
RFM-3□□-0 Protective Tube Type Flange PDF DXF
R-400 Fork Type for liquid
Model type mounting Dimension PDF Dimension DXF
RFM-401-0 Standard Type Screw-in(G1) PDF DXF
RFM-401-0 Standard Type Flange PDF DXF
RFM-4□□-0 Protective Tube Type Screw-in(G1) PDF DXF
RFM-4□□-0 Protective Tube Type Flange PDF DXF
In addition to the above specifications, we will manufacture according to any specifications. Consult our sales staff for selecting models and specifications.